The Fisher FIELDVUE DLC3010 Digital Level Controller with Fisher 249W Sensor is designed for accurate measurement of liquid level, liquid-to-liquid interface, and fluid density in industrial process vessels.

  • Two-Wire, Loop Powered Wiring Configuration
  • CL150, CL300 and CL600 Pressure Classes
Price on request
Shipping calculated at checkout.

Need help applying this product? Our engineers can help select the right equipment and design a system around your requirements. Request a quote or discuss your application with us.

// Request a quote

Fisher FIELDVUE DLC3010 HART Digital Level Controller with 249W Displacer Sensor

Sent straight to our sales team. We usually reply within one business day.

Need help choosing? Send us the part number or your operating data — talk to an engineer or see full specifications.

Product Overview

The Fisher FIELDVUE DLC3010 Digital Level Controller with Fisher 249W Sensor is designed for accurate measurement of liquid level, liquid-to-liquid interface, and fluid density in industrial process vessels. Manufactured by Fisher, an Emerson brand, this integrated measurement system uses displacer-based buoyancy sensing and digital electronics to convert changes in liquid level into a standard 4–20 mA output with HART communication. It supports continuous process monitoring, reliable measurement, and integration with industrial control systems.

The system combines the DLC3010 microprocessor-based level transmitter with the Fisher 249W cageless, wafer-style displacer sensor. As process liquid levels change, the displacer and torque tube assembly transfer movement to the controller, where a contactless Hall-effect sensor converts the movement into an electronic signal. The 249W supports installation between suitable NPS 3 or NPS 4 flanges and is available in CL150, CL300, and CL600 pressure classes. This combination is suitable for oil and gas production, chemical processing, refining, power generation, and industrial liquid level monitoring. 

Technical Specifications

Specification

Value

Product Name

Digital Level Controller with Displacer Sensor

Manufacturer / Brand

Fisher / Emerson

Controller Model

FIELDVUE DLC3010

Sensor Model

Fisher 249W

Product Type

HART Digital Liquid Level Transmitter Assembly

Measurement Variables

Liquid Level, Interface Level and Density

Measurement Principle

Displacer Buoyancy and Torque Tube

Position Sensing

Contactless Hall-Effect Sensor

Electrical Output

4–20 mA DC

Communication Protocol

HART

Wiring Configuration

Two-Wire, Loop Powered

Electrical Supply

12–30 V DC

Signal Action

Direct or Reverse Acting

Sensor Configuration

Cageless, Wafer Style

Sensor Mounting

NPS 3 or NPS 4 Raised-Face Flanges

Pressure Classes

CL150, CL300 and CL600

Measurement Span

Up to 100% of Selected Displacer Length

Standard Displacer Lengths

356 mm or 813 mm, Depending on Configuration

Controller Linearity

±0.25% of Output Span, Standalone

Combined Linearity

±0.8% of Output Span, NPS 3 249W with 14-Inch Displacer

Controller Enclosure Protection

IP66 / NEMA 4X

Process Temperature Compensation

Optional 100 Ω Platinum RTD Input

Configuration

HART Field Communicator or AMS Software

Calibration

Digital Configuration and Calibration

Controller Weight

Approximately 2.7 kg

Sensor Material

Depends on Ordered Configuration

Hazardous-Area Approval

Depends on Complete Ordering Code

Condition

New

Warranty

1 Year 

Key Features

Integrated digital level controller and displacer sensor combination

Standard 4–20 mA output with HART digital communication

Continuous measurement of liquid level, interface and density

Contactless Hall-effect sensing for accurate electronic measurement

Cageless wafer-style Fisher 249W displacer sensor

Compatible with NPS 3 and NPS 4 raised-face flange installations

Available CL150, CL300 and CL600 sensor pressure classes

Two-wire loop-powered controller with 12–30 V DC supply

Digital calibration and configuration through HART tools

Process temperature compensation capability

IP66/NEMA 4X controller enclosure for industrial environments

Compatible with Emerson AMS device management software

Typical Applications

Industrial liquid level measurement and monitoring

Oil and gas separators and processing vessels

Chemical and petrochemical processing plants

Petroleum refining and storage systems

Liquid-to-liquid interface measurement

Industrial fluid density measurement

Power generation and utility systems

Water and wastewater treatment facilities

Process tanks and pressure vessels

HART-compatible industrial process control systems

Shipping & Support

Fast dispatch – Australia & Worldwide Shipping

Technical assistance available

1-year warranty

// FAQs

Questions about this part?

Our engineers can confirm fit before you order. Contact support.

How do I find the right part for my system?

Three options. Search by part number if you have the OEM code from Parker, Danfoss, Linde, Kawasaki, Kayaba or Grundfos — our search recognises both manufacturer codes and aftermarket cross-references. Browse by category if you know the component type (pumps, valves, cylinders, etc.). Or send a spec sheet to our engineering desk and we'll cross-reference against our 3,000+ SKU catalogue within one business day.

Can you help me size a pump or valve for my application?

Yes — sizing support is included with every order. Send us your operating pressure, flow rate, viscosity, drive speed and duty cycle, and our engineers will recommend a suitable component from our catalogue with full datasheets. We don't custom-build parts ourselves, but we can spec the right OEM component for almost any standard industrial application.

Can you cross-reference a discontinued part?

Yes — cross-referencing is one of the things we do most. Send us the original part number (even if the manufacturer has dropped it) and our engineering desk will identify a current equivalent or compatible alternative. Cross-reference lookups are free and typically come back within 4 business hours.